 |
|
iPrep™ Purification Instrument
|
|
 |
Full automatic nucleic acid purification system |
|
 |
Allows prufication of nucleic acid from up to 13 samples in 18 min. |
|
 |
Allows purification of DNA from Forensic,Buccal, tissue and blood samples. |
|
 |
Allows purification of RNA from tissue,blood and cells. |
|
 |
Purifies viral DNA/RNA from serum and plasma samples |
|
 |
Works with operational cartridge system. No need of any materials except the kit. |
|
 |
Featured of barcode reader. |
|
 |
www.invitrogen.com/iprep |
|
| Datasheet & Flayer |
|
|
|
| .................................... |
.. |
....................................................................................................... |
 |
|
|
| .................................... |
.. |
....................................................................................................... |
 |
|
| CAPP Ecopipette™ ve CappAero™ pipet systems |
|
 |
Single-channel, 8- channel and 12- channel controllable, normal and electronic pipets and sigle channel stable volumed single channel pipets are available. |
|
 |
Completely autoclavable. |
|
 |
Comprises of double O-Ring system which is inhibitor of leakage. |
|
 |
Waranty for 3 years |
|
 |
www.cappbrand.com |
|
| Datasheet & Flayer |
|
|
|
| .................................... |
.. |
....................................................................................................... |
 |
|
| iBlot® Dry Blotting System |
|
 |
Performs protein blotting (western blot) or DNA blotting (Sauthern blot) within 7 min. |
|
 |
No need of any buffer or an extra power supply. |
|
 |
Capable of blotting 2 mini or 1 midi gel |
|
 |
Applicable with PVDF and Nitrocellulose membrane |
|
 |
www.invitrogen.com/iblot |
|
| Datasheet & Flayer |
|
|
|
| .................................... |
.. |
....................................................................................................... |
 |
|
| BenchPro™ 4100 Card Processing Station |
|
 |
Full automatic western blot detection platform. |
|
 |
Capable of running 4 western blot (mini or midi) membrane at the same time. |
|
 |
Since this is an open system, it can work with chemiluminescence and chromogen kits or reactives. |
|
 |
Provides building of 3 optimized protocol and 20 custom programmes. |
|
 |
www.invitrogen.com/benchpro |
|
| Datasheet & Flayer |
|
|
|
| .................................... |
.. |
....................................................................................................... |
 |
|
| Mygene L series Thermal Cyclers |
|
 |
New generation Peltier- based, normal and gradient thermal cycler. |
|
 |
Comprises large 5,7 coloured and diagonal LCD screen. |
|
 |
Featured recording of 120 programme. The memory can be extended unlimited with USB memory. |
|
 |
Provides possibility of multiple nesting loop (30 steps), Long PCR and Touchdown PCR |
|
 |
Compatible with 0,2 ml and 0,5 ml PCR tubes, 8/12x PCR tube strips, 96 well PCR plate and in-situ plate. |
|
 |
Featured combi block(96 well 0,2 ml +77 well 0,5 ml). |
|
 |
Featured automotically start, pause, power take off and holding +4 C . |
|
 |
www.longgene.co/en/products.asp |
|
| Datasheet & Flayer |
|
|
|
| .................................... |
.. |
....................................................................................................... |
 |
|
| HybriMax “Flow-through Hybridization” System |
|
 |
Detects 21 HPV Genotype with HPV GenoaArray kit. |
|
 |
1) High-risk : HPV 16,18,31,33, 35,39, 45,51, 52, HPV53,56,58,59,66,68 |
|
 |
2) Low-risk : HPV 6,11,42,43,44,CP8304 |
|
 |
Works with PCR and Hybridization procedure |
|
 |
www.hybribio.com |
|
| Datasheet & Flayer |
|
|
|
| .................................... |
.. |
....................................................................................................... |
 |
|
| Neon Transfection System |
|
 |
Efficiency up to % 90 in many cell types, including difficult-to transfect cells,primary and stem cells. |
|
 |
Suitable for tarnfection of DNA,RNAi(siRNA) . |
|
 |
Open system allows electroporation parameters to be optimized easily. |
|
 |
For all cell types only one reactive kit can be used. There are easy to use protocols optimized for various cell types. |
|
 |
Capable of transfecting cells from 2x104 to 2x106 for per reaction. |
|
 |
www.invitrogen.com/neon |
|
| Datasheet & Flayer |
|
|
|
| .................................... |
.. |
....................................................................................................... |
 |
|
| Qubit® Quantitation Platform |
|
 |
Provides quantity detectiton of dsDNA, ssDNA, RNA and protein. |
|
 |
Working sample volume is 1-20 ul. |
|
 |
Last calibration is saved |
|
 |
PC analysis programme lets reporting measurements in Excell format |
|
 |
www.invitrogen.com/qubit |
|
| Datasheet & Flayer |
|
|
|
| .................................... |
.. |
....................................................................................................... |
 |
|
| E-Gel iBase and E-Gel Safe Imager Combo Kit |
|
 |
Enables real- time imaging possibility of DNA migration. |
|
 |
Suitable to use with SYBR safe and ETBR gels. |
|
 |
Featured automatic power take off and reverse run. |
|
 |
Includes programme selection option and time control. |
|
 |
www.invitrogen.com |
|
| Datasheet & Flayer |
|
|
|
| .................................... |
.. |
....................................................................................................... |
 |
|
| Powerease 500 power supply |
|
 |
Suitable for mini-gel electrophorese |
|
 |
8 optimized and 4 custom methods are avilable. |
|
 |
On the LCD screen, stable voltage, or power options are available. |
|
 |
Featured optional buffer temperature monitoring. |
|
 |
Experimental results can be printed out |
|
 |
www.invitrogen.com |
|
| Datasheet & Flayer |
|
|
|
|
|
|
|
|
|
|
|
|